Mixer extension tube 2K NE
SKU 9046435-12
Original price
€17,50
-
Original price
€17,50
Original price
€17,50
-
Current price
Mixer extension tube 2K NE, 12 ST
Main features short:
Fire resistance up to S90
Economical, time-saving installation
Application areas:
Masonry, concrete, reinforced concrete, aerated concrete walls, lightweight partitions with wooden or steel studs; Concrete, reinforced concrete, aerated concrete ceilings. . Minimum component thickness:. 10 centimeters. . Minimum bulkhead thickness:. 20 cm. . Max bulkhead size:. 45 x 45 cm (W x H) or Ø 300 mm
Hints:
Part II of the List of Technical Building Regulations (LTB) generally prescribes compulsory training for combined insulation (Annex 1 / 7 LTB Part II). Combination seals according to a general building permit may only be created by companies whose staff have been trained by the manufacturer of the seal system in accordance with the specifications of the permit.
More information at www.bti.de/brandschutz
Characteristics:
Fire resistance up to S90
Economical, time-saving installation. No coating required. Fabric adhesive tape is sufficient as a formwork aid (included in the scope of delivery)
Clean and simple processing. Foam can be placed at the desired location due to the high material viscosity
Optimized coordination between the start of the reaction and curing. Sufficiently long work interruptions possible (approx. 50 seconds)
Simple reassignment. Foam remains permanently elastic after curing
For execution, the general type approval Z-19.53-2529 or the general type approval Z-19.53-2322 must be observed
Main features short:
Fire resistance up to S90
Economical, time-saving installation
Application areas:
Masonry, concrete, reinforced concrete, aerated concrete walls, lightweight partitions with wooden or steel studs; Concrete, reinforced concrete, aerated concrete ceilings. . Minimum component thickness:. 10 centimeters. . Minimum bulkhead thickness:. 20 cm. . Max bulkhead size:. 45 x 45 cm (W x H) or Ø 300 mm
Hints:
Part II of the List of Technical Building Regulations (LTB) generally prescribes compulsory training for combined insulation (Annex 1 / 7 LTB Part II). Combination seals according to a general building permit may only be created by companies whose staff have been trained by the manufacturer of the seal system in accordance with the specifications of the permit.
More information at
Characteristics:
Fire resistance up to S90
Economical, time-saving installation. No coating required. Fabric adhesive tape is sufficient as a formwork aid (included in the scope of delivery)
Clean and simple processing. Foam can be placed at the desired location due to the high material viscosity
Optimized coordination between the start of the reaction and curing. Sufficiently long work interruptions possible (approx. 50 seconds)
Simple reassignment. Foam remains permanently elastic after curing
For execution, the general type approval Z-19.53-2529 or the general type approval Z-19.53-2322 must be observed