PS Cable Tube CT 116 x 300 mm
SKU 9089386
Original price
€114,49
-
Original price
€114,49
Original price
€114,49
-
Current price
PS- Cable Tube CT 116 x 300 mm, 1 ST
Main features short:
Fire resistance S90
100% occupancy of the cable tube is possible
Application areas:
For solid walls and ceilings, particularly suitable for light partition walls. In order to achieve the required bulkhead thickness, it is not necessary to double the light partition walls.
Hints:
For easy installation, the length of the PS cable tube should at least correspond to the component thickness of the wall/ceiling (regardless of the media that are fed through).
The sealing plug can be cut to size to close the remaining opening of the PS Cable Tube. The stopper must be coated with FL Tec A fire protection filler, item no. 9 081595. layer thickness 2 mm (1 mm dry layer thickness)
The gussets between the installations are to be sealed with the FL Tec A fire protection filler item no. 9 081595.
. Important:. All assignment variants that can be assigned to the group electrical lines/installations (cables, electrical installation pipes (EIR), speed pipes) may be routed together in one cable tube. Air conditioning split lines must be routed in a separate cable tube.
Characteristics:
Easy installation even with existing lines. Cable Tube consists of two half-shells with a click fastener
No reveal formation required in the lightweight partition wall
100% occupancy of the cable tube is possible
Electrical conduit up to Ø 40 mm with/without cable up to Ø 21 mm
Cable up to Ø 80 mm
Cable bundles up to Ø 100 mm with cables up to Ø 21 mm
Simple reassignment
No cable coating required
For processing in the system:. PS Cable Tube CT Z-19.53-2324. Fire protection mortar PS Novasit Combi Z-19.53-2428. Mineral fiber combination seal FL Tec A Z-19.53-2329
Scope of delivery:
PS Cable Tube CT: 1 cable tube incl. 2 sealing plugs
PS melamine Plug set: 10 pieces sealing plugs
Main features short:
Fire resistance S90
100% occupancy of the cable tube is possible
Application areas:
For solid walls and ceilings, particularly suitable for light partition walls. In order to achieve the required bulkhead thickness, it is not necessary to double the light partition walls.
Hints:
For easy installation, the length of the PS cable tube should at least correspond to the component thickness of the wall/ceiling (regardless of the media that are fed through).
The sealing plug can be cut to size to close the remaining opening of the PS Cable Tube. The stopper must be coated with FL Tec A fire protection filler, item no. 9 081595. layer thickness 2 mm (1 mm dry layer thickness)
The gussets between the installations are to be sealed with the FL Tec A fire protection filler item no. 9 081595.
. Important:. All assignment variants that can be assigned to the group electrical lines/installations (cables, electrical installation pipes (EIR), speed pipes) may be routed together in one cable tube. Air conditioning split lines must be routed in a separate cable tube.
Characteristics:
Easy installation even with existing lines. Cable Tube consists of two half-shells with a click fastener
No reveal formation required in the lightweight partition wall
100% occupancy of the cable tube is possible
Electrical conduit up to Ø 40 mm with/without cable up to Ø 21 mm
Cable up to Ø 80 mm
Cable bundles up to Ø 100 mm with cables up to Ø 21 mm
Simple reassignment
No cable coating required
For processing in the system:. PS Cable Tube CT Z-19.53-2324. Fire protection mortar PS Novasit Combi Z-19.53-2428. Mineral fiber combination seal FL Tec A Z-19.53-2329
Scope of delivery:
PS Cable Tube CT: 1 cable tube incl. 2 sealing plugs
PS melamine Plug set: 10 pieces sealing plugs