Fire protection sleeve IWM III plus
SKU 9021116-10
Original price
€469,62
-
Original price
€469,62
Original price
€469,62
-
Current price
Fire protection sleeve IWM III plus, 10 M
Main features short:
For R90 wall and ceiling penetrations of flammable pipelines up to Ø 200 mm
Application areas:
For plumbing and heating lines, waste water lines, lines for non-flammable liquids or gases (not suitable for ventilation lines, see approval notice). . IWM III plus:. up to Ø 200 mm for solid ceilings. up to Ø 160 mm for solid walls. up to Ø 110 mm for light partition walls. . IWM III plus ISO:. up to Ø 110 mm with or without synthetic rubber insulation from 6 to 32 mm
Hints:
More information at www.bti.de/brandschutz
Processing instructions:
Wall duct: Attach a fire protection insert to each side of the wall. Ceiling duct: Attach a fire protection insert to the underside of the ceiling. Residual joints of up to 9 mm (IWM III plus) or up to 16 mm (IWM III plus ISO) can be sealed with fire protection putty RK 1000. Please note the General Building Inspectorate Approval.
Characteristics:
Installation in the wall / ceiling
Pipe bends can be mounted directly behind the wall/ceiling. Optimum use of the room height with gravity lines
Optimum warehousing and construction site logistics. Supplied as roll goods, this means that pipe dimensions up to Ø 200 mm can be sealed off universally with one product
The general type approval Z-19.53-2371 IWM III plus or Z-19.17-1884 IWM III plus ISO must be observed for the approval-compliant and safe design
Equipped with self-adhesive. Easy to install, even in hard-to-reach places, as the tape only has to be glued around the pipeline to be sealed off
High security. No longer slips unintentionally after installation, but remains in the correct position for the function even when the cover is closed
Little need for space. Individual partitions can be laid one below the other with a 0-distance
Safe structure-borne noise decoupling. Noise protection hose PE up to 5 mm thick can be fed through the wall / ceiling
Also suitable for installation in damp rooms
Main features short:
For R90 wall and ceiling penetrations of flammable pipelines up to Ø 200 mm
Application areas:
For plumbing and heating lines, waste water lines, lines for non-flammable liquids or gases (not suitable for ventilation lines, see approval notice). . IWM III plus:. up to Ø 200 mm for solid ceilings. up to Ø 160 mm for solid walls. up to Ø 110 mm for light partition walls. . IWM III plus ISO:. up to Ø 110 mm with or without synthetic rubber insulation from 6 to 32 mm
Hints:
More information at
Processing instructions:
Wall duct: Attach a fire protection insert to each side of the wall. Ceiling duct: Attach a fire protection insert to the underside of the ceiling. Residual joints of up to 9 mm (IWM III plus) or up to 16 mm (IWM III plus ISO) can be sealed with fire protection putty RK 1000. Please note the General Building Inspectorate Approval.
Characteristics:
Installation in the wall / ceiling
Pipe bends can be mounted directly behind the wall/ceiling. Optimum use of the room height with gravity lines
Optimum warehousing and construction site logistics. Supplied as roll goods, this means that pipe dimensions up to Ø 200 mm can be sealed off universally with one product
The general type approval Z-19.53-2371 IWM III plus or Z-19.17-1884 IWM III plus ISO must be observed for the approval-compliant and safe design
Equipped with self-adhesive. Easy to install, even in hard-to-reach places, as the tape only has to be glued around the pipeline to be sealed off
High security. No longer slips unintentionally after installation, but remains in the correct position for the function even when the cover is closed
Little need for space. Individual partitions can be laid one below the other with a 0-distance
Safe structure-borne noise decoupling. Noise protection hose PE up to 5 mm thick can be fed through the wall / ceiling
Also suitable for installation in damp rooms